{"id":255,"date":"2026-08-01T13:39:50","date_gmt":"2026-08-01T05:39:50","guid":{"rendered":"https:\/\/www.kolitai.com\/?p=255"},"modified":"2026-08-01T13:39:50","modified_gmt":"2026-08-01T05:39:50","slug":"kt-e550-constant-temperature-and-humidity-test-chamber-baking-paint-casing","status":"publish","type":"post","link":"https:\/\/www.kolitai.com\/?p=255","title":{"rendered":"KT-E550 Constant Temperature and Humidity Test Chamber (Baking Paint Casing)"},"content":{"rendered":"\n<h3 class=\"wp-block-heading\">Application<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The constant temperature and humidity test chamber adopts high-stability platinum PT-100 temperature measuring resistors, equipped with Chinese &amp; English LCD touch screen and multiple sets of PID control functions. It is fitted with RS-232C\/485C computer communication interface for upper computer control. The equipment is capable of simulating various environmental conditions including high temperature &amp; high humidity, high temperature &amp; low humidity, low temperature &amp; high humidity, single high temperature and single low temperature. Meanwhile, it is equipped with user-friendly, high-precision programming control and fixed-point control system to deliver excellent test performance.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Compliance Standards<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">GB\/T 11158-2008 Technical Conditions for High Temperature Test Chambers<br>GB\/T 10589-2008 Technical Conditions for Low Temperature Test Chambers<br>GB\/T 5170.2-2008 Test Equipment for Temperature<br>GB\/T 5170.5-2008 Test Equipment for Temperature and Humidity<br>GB\/T 2423.1-2008 (IEC60068-2-1:2007) Test Ab: Low-temperature Test Method<br>GB\/T 2423.2-2008 (IEC60068-2-2:2007) Test Bb: High-temperature Test Method<br>GB\/T 2423.3-2008 (IEC60068-2-3:2007) Test Ca: Steady-state Damp Heat Test<br>GB\/T 2423.4-2008 (IEC60068-2-30:2005) Test Db: Cyclic Damp Heat Test<br>GJB 150.3A-2009 (MIL-STD-810F-2000) High Temperature Test<br>GJB 150.4A-2009 (MIL-STD-810F-2000) Low Temperature Test<br>GJB 150.9A-2009 (MIL-STD-810F-2000) Damp Heat Test<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td colspan=\"2\">Model<\/td><td colspan=\"13\">KT-E550<\/td><\/tr><tr><td colspan=\"2\">Inner Volume (L)<\/td><td colspan=\"3\">50<\/td><td colspan=\"6\">80<\/td><td colspan=\"4\">100<\/td><\/tr><tr><td colspan=\"2\">Internal Dimension (mm, W<em>H<\/em>D)<\/td><td colspan=\"3\">350*300*400<\/td><td colspan=\"6\">400*400*500<\/td><td colspan=\"4\">500*400*500<\/td><\/tr><tr><td colspan=\"2\">External Dimension (mm, W<em>H<\/em>D)<\/td><td colspan=\"3\">500*900*1300<\/td><td colspan=\"6\">600*950*1350<\/td><td colspan=\"4\">700*950*1530<\/td><\/tr><tr><td colspan=\"2\">Packing Volume (CBM)<\/td><td colspan=\"2\">3<\/td><td colspan=\"3\">3.5<\/td><td colspan=\"2\">4.5<\/td><td colspan=\"3\">5.5<\/td><td colspan=\"3\">6<\/td><\/tr><tr><td colspan=\"2\">Gross Weight (KGS)<\/td><td colspan=\"2\">320<\/td><td colspan=\"3\">350<\/td><td colspan=\"2\">400<\/td><td colspan=\"3\">600<\/td><td colspan=\"3\">700<\/td><\/tr><tr><td colspan=\"2\">Temperature Range<\/td><td colspan=\"13\">-80\u2103, -73\u2103, -60\u2103, -40\u2103, -20\u2103, 0\u2103\uff5e+150\u2103, +200\u2103 (300\u2103)-65\u2103~150\u2103<\/td><\/tr><tr><td>Performance<\/td><td>Temperature Range<\/td><td colspan=\"13\">-65\u2103~150\u2103<\/td><\/tr><tr><td>&nbsp;<\/td><td>Temperature Fluctuation<\/td><td colspan=\"13\">\u00b10.5\u2103 (Atmospheric Pressure)<\/td><\/tr><tr><td>&nbsp;<\/td><td>Temperature Deviation<\/td><td colspan=\"13\">\u00b12.0\u2103 (Atmospheric Pressure)<\/td><\/tr><tr><td>&nbsp;<\/td><td>Temperature Rise Time<\/td><td colspan=\"13\">\u226460min (+20\u2103~+150\u2103, atmospheric pressure, no load)<\/td><\/tr><tr><td>&nbsp;<\/td><td>Humidity Range<\/td><td colspan=\"13\">20%RH~98%RH (Optional:10%RH~98%RH \/ 5%RH~98%RH)<\/td><\/tr><tr><td>&nbsp;<\/td><td>Temp. &amp; Humidity Fluctuation<\/td><td colspan=\"13\">\u00b10.2\u2103, \u00b10.5%RH<\/td><\/tr><tr><td>&nbsp;<\/td><td>Temperature Drop Time<\/td><td colspan=\"13\">\u226445min (Normal Pressure RP) \/ \u226460min (Normal Pressure RP) \/ \u226490min (Normal Pressure RP)<\/td><\/tr><tr><td>&nbsp;<\/td><td>Pressure Range<\/td><td colspan=\"13\">Normal Pressure RP ~ 0.5KPa<\/td><\/tr><tr><td>&nbsp;<\/td><td>Pressure Control Tolerance<\/td><td colspan=\"13\">\u00b10.1KPa (\u22642KPa), \u00b15% (2KPa~40KPa), \u00b12KPa (\u226540KPa)<\/td><\/tr><tr><td>&nbsp;<\/td><td>Pressure Reduction Time<\/td><td>\u226420min<\/td><td colspan=\"3\">\u226425min<\/td><td colspan=\"4\">\u226430min<\/td><td colspan=\"3\">\u226445min<\/td><td colspan=\"2\">\u226450min<\/td><\/tr><tr><td colspan=\"2\">Operating Ambient<\/td><td colspan=\"13\">Temp: +5\u2103~+35\u2103; Humidity: \u226490%RH; Atmospheric pressure: 86-106KPa<\/td><\/tr><tr><td>Material<\/td><td>Shell Material<\/td><td colspan=\"13\">Stainless steel + baking paint<\/td><\/tr><tr><td>&nbsp;<\/td><td>Inner Chamber Material<\/td><td colspan=\"13\">SUS#304 stainless steel plate<\/td><\/tr><tr><td>&nbsp;<\/td><td>Insulation Material<\/td><td colspan=\"13\">PU glass wool<\/td><\/tr><tr><td>System<\/td><td>Air Circulation System<\/td><td colspan=\"13\">Heat dissipation fan<\/td><\/tr><tr><td>&nbsp;<\/td><td>Heating System<\/td><td colspan=\"13\">SUS#304 stainless steel high-speed heater<\/td><\/tr><tr><td>&nbsp;<\/td><td>Humidifying System<\/td><td colspan=\"13\">Imported Tecumseh compressor (or German Bitzer compressor) + fin evaporator + air-cooled (water-cooled) condenser<\/td><\/tr><tr><td>&nbsp;<\/td><td>Dehumidifying System<\/td><td colspan=\"13\">ADP critical dew point cooling &amp; dehumidifying method<\/td><\/tr><tr><td>&nbsp;<\/td><td>Control System<\/td><td colspan=\"13\">Digital indicator + SSR + PID<\/td><\/tr><tr><td colspan=\"2\">Rated Power (KW)<\/td><td colspan=\"3\">8<\/td><td colspan=\"3\">10<\/td><td colspan=\"3\">12<\/td><td colspan=\"3\">15<\/td><td>20<\/td><\/tr><tr><td colspan=\"2\">Water Supply Accessories<\/td><td colspan=\"13\">2 sets of sample racks, 1 piece of 3m power cord, pressure test port<\/td><\/tr><tr><td colspan=\"2\">Protection Devices<\/td><td colspan=\"13\">Overheat protection circuit breaker, compressor overload protection, control system overload protection, humidification system overload protection, overload indicator light<\/td><\/tr><tr><td colspan=\"2\">Power Supply<\/td><td colspan=\"13\">AC 3-phase 380V 50\/60Hz<\/td><\/tr><tr><td colspan=\"2\">Custom Service<\/td><td colspan=\"13\">Non-standard special requirements are acceptable for customization<\/td><\/tr><\/tbody><\/table><\/figure>\n","protected":false},"excerpt":{"rendered":"<p>Application The constant temperature and humidity test  [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":256,"comment_status":"closed","ping_status":"","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[28],"tags":[],"class_list":["post-255","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-environmental-test-chamber"],"_links":{"self":[{"href":"https:\/\/www.kolitai.com\/index.php?rest_route=\/wp\/v2\/posts\/255","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.kolitai.com\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.kolitai.com\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.kolitai.com\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.kolitai.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=255"}],"version-history":[{"count":1,"href":"https:\/\/www.kolitai.com\/index.php?rest_route=\/wp\/v2\/posts\/255\/revisions"}],"predecessor-version":[{"id":257,"href":"https:\/\/www.kolitai.com\/index.php?rest_route=\/wp\/v2\/posts\/255\/revisions\/257"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.kolitai.com\/index.php?rest_route=\/wp\/v2\/media\/256"}],"wp:attachment":[{"href":"https:\/\/www.kolitai.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=255"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.kolitai.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=255"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.kolitai.com\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=255"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}