{"id":299,"date":"2026-08-01T16:50:38","date_gmt":"2026-08-01T08:50:38","guid":{"rendered":"https:\/\/www.kolitai.com\/?p=299"},"modified":"2026-08-01T16:50:38","modified_gmt":"2026-08-01T08:50:38","slug":"kt-e670-constant-temperature-and-humidity-test-chamber","status":"publish","type":"post","link":"https:\/\/www.kolitai.com\/?p=299","title":{"rendered":"KT-E670 Constant Temperature and Humidity Test Chamber"},"content":{"rendered":"\n<h3 class=\"wp-block-heading\">Product Application<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">This chamber is mainly applied for adaptability tests of finished products, components and materials (electronics, electrical appliances, food, automobile parts, rubber &amp; plastics, metal materials, etc.) during storage, transportation and service under alternating high-low temperature and humid-heat environments.<br>It serves as reliability testing equipment for cold resistance, heat resistance, humidity resistance and dry resistance tests on raw materials and components of electronics, electrical products and plastic products for quality control projects.<br>It is especially suitable for cyclic high temperature, low temperature and damp resistance tests for optical fibers, LCDs, crystals, inductors, PCBs, batteries, computers, mobile phones, rubber and plastic products.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Compliant Standards<\/h3>\n\n\n\n<ol class=\"wp-block-list\">\n<li>GB\/T 11158-2008: Specification for high temperature test chambers<\/li>\n\n\n\n<li>GB\/T 10589-2008: Specification for low temperature test chambers<\/li>\n\n\n\n<li>GB\/T 5170.2-2008: Test equipment for temperature testing<\/li>\n\n\n\n<li>GB\/T 5170.5-2008: Test equipment for damp-heat testing<\/li>\n\n\n\n<li>GB\/T 2423.1-2008 (IEC60068-2-1:2007): Test Ab: Low-temperature test method<\/li>\n\n\n\n<li>GB\/T 2423.2-2008 (IEC60068-2-2:2007): Test Bb: Dry heat test method<\/li>\n\n\n\n<li>GB\/T 2423.3-2008 (IEC60068-2-3:2007): Test Ca: Steady-state damp heat test<\/li>\n\n\n\n<li>GB\/T 2423.4-2008 (IEC60068-2-30:2005): Test Db: Alternating damp heat test<\/li>\n\n\n\n<li>GJB150.3A-2009 (MIL-STD-810F-2000): High temperature test<\/li>\n\n\n\n<li>GJB150.4A-2009 (MIL-STD-810F-2000): Low temperature test<\/li>\n\n\n\n<li>GJB150.9A-2009 (MIL-STD-810F-2000): Humidity test<\/li>\n<\/ol>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td colspan=\"2\">Model<\/td><td colspan=\"2\">KT-E650-150<\/td><td colspan=\"2\">KT-E650-225<\/td><td colspan=\"3\">KT-E650-408<\/td><td colspan=\"3\">KT-E650-800<\/td><td colspan=\"2\">KT-E650-1000<\/td><\/tr><tr><td colspan=\"2\">Inner Volume (L)<\/td><td colspan=\"2\">150<\/td><td colspan=\"2\">225<\/td><td colspan=\"3\">408<\/td><td colspan=\"3\">800<\/td><td colspan=\"2\">1000<\/td><\/tr><tr><td colspan=\"2\">Internal Dimension (mm, W<em>H<\/em>D)<\/td><td colspan=\"2\">500*600*500<\/td><td colspan=\"2\">500*750*600<\/td><td colspan=\"3\">600*850*800<\/td><td colspan=\"3\">1000*1000*800<\/td><td colspan=\"2\">1000*1000*1000<\/td><\/tr><tr><td colspan=\"2\">External Dimension (mm, W<em>H<\/em>D)<\/td><td colspan=\"2\">1000-1600*1400<\/td><td colspan=\"2\">1000*1750*1500<\/td><td colspan=\"3\">110*1850*1700<\/td><td colspan=\"3\">1500*2000*1700<\/td><td colspan=\"2\">1850*1600*2250<\/td><\/tr><tr><td colspan=\"2\">Packing Volume (CBM)<\/td><td colspan=\"2\">3<\/td><td colspan=\"2\">3.5<\/td><td colspan=\"3\">4.5<\/td><td colspan=\"3\">5.5<\/td><td colspan=\"2\">6<\/td><\/tr><tr><td colspan=\"2\">Gross Weight (KGS)<\/td><td colspan=\"2\">320<\/td><td colspan=\"2\">350<\/td><td colspan=\"3\">400<\/td><td colspan=\"3\">600<\/td><td colspan=\"2\">700<\/td><\/tr><tr><td colspan=\"2\">Temperature Range<\/td><td colspan=\"12\">-80\u2103, -73\u2103, -60\u2103, -40\u2103, -20\u2103, 0\u2103\uff5e+150\u2103, +200\u2103 (300\u2103)-65\u2103~150\u2103<\/td><\/tr><tr><td rowspan=\"10\">Performance<\/td><td>Temperature Range<\/td><td colspan=\"12\">-65\u2103~150\u2103<\/td><\/tr><tr><td>Temperature Fluctuation<\/td><td colspan=\"12\">\u00b10.5\u2103 (Atmospheric Pressure)<\/td><\/tr><tr><td>Temperature Deviation<\/td><td colspan=\"12\">\u00b12.0\u2103 (Atmospheric Pressure)<\/td><\/tr><tr><td>Temperature Rise Time<\/td><td colspan=\"12\">\u226460min (+20\u2103~+150\u2103, atmospheric pressure, no load)<\/td><\/tr><tr><td>Humidity Range<\/td><td colspan=\"12\">20%RH~98%RH (Optional:10%RH~98%RH \/ 5%RH~98%RH)<\/td><\/tr><tr><td>Temp. &amp; Humidity Fluctuation<\/td><td colspan=\"12\">\u00b10.2\u2103, \u00b10.5%RH<\/td><\/tr><tr><td>Temperature Drop Time<\/td><td colspan=\"12\">\u226445min (Normal Pressure RP) \/ \u226460min (Normal Pressure RP) \/ \u226490min (Normal Pressure RP)<\/td><\/tr><tr><td>Pressure Range<\/td><td colspan=\"12\">Normal Pressure RP ~ 0.5KPa<\/td><\/tr><tr><td>Pressure Control Tolerance<\/td><td colspan=\"12\">\u00b10.1KPa (\u22642KPa), \u00b15% (2KPa~40KPa), \u00b12KPa (\u226540KPa)<\/td><\/tr><tr><td>Pressure Reduction Time<\/td><td>\u226420min<\/td><td colspan=\"3\">\u226425min<\/td><td colspan=\"2\">\u226430min<\/td><td colspan=\"3\">\u226445min<\/td><td colspan=\"3\">\u226450min<\/td><\/tr><tr><td colspan=\"2\">Operating Ambient<\/td><td colspan=\"12\">Temp: +5\u2103~+35\u2103; Humidity: \u226490%RH; Atmospheric pressure: 86-106KPa<\/td><\/tr><tr><td rowspan=\"3\">Material<\/td><td>Shell Material<\/td><td colspan=\"12\">Stainless steel + baking paint<\/td><\/tr><tr><td>Inner Chamber Material<\/td><td colspan=\"12\">SUS#304 stainless steel plate<\/td><\/tr><tr><td>Insulation Material<\/td><td colspan=\"12\">PU glass wool<\/td><\/tr><tr><td rowspan=\"5\">System<\/td><td>Air Circulation System<\/td><td colspan=\"12\">Heat dissipation fan<\/td><\/tr><tr><td>Heating System<\/td><td colspan=\"12\">SUS#304 stainless steel high-speed heater<\/td><\/tr><tr><td>Humidifying System<\/td><td colspan=\"12\">Imported Tecumseh compressor (or German Bitzer compressor) + fin evaporator + air-cooled (water-cooled) condenser<\/td><\/tr><tr><td>Dehumidifying System<\/td><td colspan=\"12\">ADP critical dew point cooling &amp; dehumidifying method<\/td><\/tr><tr><td>Control System<\/td><td colspan=\"12\">Digital indicator + SSR + PID<\/td><\/tr><tr><td colspan=\"2\">Rated Power (KW)<\/td><td colspan=\"3\">8<\/td><td colspan=\"2\">10<\/td><td colspan=\"3\">12<\/td><td colspan=\"3\">15<\/td><td>20<\/td><\/tr><tr><td colspan=\"2\">Water Supply Accessories<\/td><td colspan=\"12\">2 sets of sample racks, 1 piece of 3m power cord, pressure test port<\/td><\/tr><tr><td colspan=\"2\">Protection Devices<\/td><td colspan=\"12\">Overheat protection circuit breaker, compressor overload protection, control system overload protection, humidification system overload protection, overload indicator light<\/td><\/tr><tr><td colspan=\"2\">Power Supply<\/td><td colspan=\"12\">AC 3-phase 380V 50\/60Hz<\/td><\/tr><tr><td colspan=\"2\">Custom Service<\/td><td colspan=\"12\">Non-standard special requirements are acceptable for customization<\/td><\/tr><\/tbody><\/table><\/figure>\n","protected":false},"excerpt":{"rendered":"<p>Product Application This chamber is mainly applied for  [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":300,"comment_status":"closed","ping_status":"","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[28],"tags":[],"class_list":["post-299","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-environmental-test-chamber"],"_links":{"self":[{"href":"https:\/\/www.kolitai.com\/index.php?rest_route=\/wp\/v2\/posts\/299","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.kolitai.com\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.kolitai.com\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.kolitai.com\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.kolitai.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=299"}],"version-history":[{"count":1,"href":"https:\/\/www.kolitai.com\/index.php?rest_route=\/wp\/v2\/posts\/299\/revisions"}],"predecessor-version":[{"id":301,"href":"https:\/\/www.kolitai.com\/index.php?rest_route=\/wp\/v2\/posts\/299\/revisions\/301"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.kolitai.com\/index.php?rest_route=\/wp\/v2\/media\/300"}],"wp:attachment":[{"href":"https:\/\/www.kolitai.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=299"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.kolitai.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=299"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.kolitai.com\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=299"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}